Laser Wavelength
|
1550 ± 2 nm
|
Distance Range
|
100 m ~ 80km (Step: 100m, 1 km, 10 km)
|
Measurement Frequency Range
|
9 ~ 13 GHz
|
Range of strain measurements
|
-30,000 to +40,000 με (-3% to +4%)
|
Measurement Frequency Scan Step
|
5, 10, 20, 50 MHz
|
Readout Resolution
|
5 cm, 10 cm, 20 cm, 50 cm, 100 cm
|
Sampling Points
|
600,000 (maximum)
|
Pump Pulse-light Output
|
20dBm ~ 30dBm (1dB step)
|
Probe CW-light Output
|
-5dBm ~ +5dBm (1dB step)
|
Average Count Settings
|
28 ~ 224 times
|
|
BOTDR
|
Pulse width (ns)
|
5
|
10
|
20
|
50
|
100
|
200
|
500
|
1000 |
Spatial resolution (m)
|
0.5
|
1
|
2
|
5
|
10
|
20
|
50
|
100 |
Dynamic Range (dB) *1
|
3
|
5
|
8
|
12
|
15
|
16
|
22
|
24 |
Approx. Max Measurement Distance (km) *1*2
|
1
|
15
|
25
|
40
|
45
|
50
|
70
|
80 |
|
PPP-BOTDA
|
Pulse width (ns)
|
1
|
2
|
5
|
10
|
-
|
-
|
-
|
-
|
Spatial resolution (m)
|
0.1
|
0.2
|
0.5
|
1
|
-
|
-
|
-
|
-
|
Dynamic Range (dB) *1
|
2
|
3.5
|
6
|
8
|
-
|
-
|
-
|
-
|
Approx. Max Measurement Distance (km) *1*2
|
5
|
10
|
20
|
25
|
-
|
-
|
-
|
-
|
Strain Measurement Accuracy *3
|
BOTDR= 40με
PPP-BOTDA= 20με
|
Temperature Measurement Accuracy *3*4
|
BOTDR= 2.0°C
PPP-BOTDA= 1.0°C
|
Repeatability *3*4*5
|
BOTDR= 20 με / 1.0°C
PPP-BOTDA= 10 με / 0.5°C
|
|
COTDR
|
Pulse width (ns)
|
5
|
10
|
20
|
50
|
100
|
200
|
500
|
1000
|
Spatial resolution (m)
|
0.5
|
1
|
2
|
5
|
10
|
20
|
50
|
100
|
Dynamic Range (dB) *1
|
10
|
13
|
16
|
20
|
23
|
26
|
30
|
30
|
Approx. Max Measurement Distance (km) *1*2
|
27
|
40
|
50
|
60
|
70
|
80
|
80
|
80
|
High-speed Measurement
|
FS Mode *6 |
< 15 Hz
|
AT Mode *7 |
< 550 Hz
|
Fiber Connector |
FC-APC (factory default)
|
Suitable fiber
|
Single mode optical fiber
|
Interface
|
USB 2.0 x4, LAN(RJ-45) x2, RGB x 1
|
Power Supply
|
|
Laser Class
|
Class 1 (IEC60825-1 : 2001)
|
Dimensions / Weight
|
approx. 456(W) × 485(D) ×286(H) mm / 30 kg
|
Operating Temperature
|
|
Storage Temperature
|
0~50 °C
|
Place of Production
|
Japan
|
|
(2019/11/18)
*1 Based on 2^16 average cycles.
*2 Based on average fiber loss of 0.3 dB/km using single mode fiber.
*3 Based on the measurement of strain-free, UV-coated fiber.
*4 Based on the measurement with strain-free, UV-coated fiber and in constant temperature environment.
*5 Maximum standard deviation of measurement value in 5 consecutive measurements for 100 consecutive points.
*6 The setting of 50m range, 2^8 count settings, 41 scanning steps in batch processing mode. (PPP-BOTDA only).
*7 The settings of 50m range, 2^8 count settings, 1 scanning step in batch processing mode.
*1-*5 are all based on a frequency scan step of 5 MHz with Pre-Pump Adjustment on.